Septic tank size and materials

A house with 1 or 2 bedrooms needs a septic tank of 2,838 litres (NPC Table B-2). A 3-bedroom house is sized at 3,785 litres, which as a 6" hollow block tank is 2.45 × 1.30 m inside and 1.5 m deep, built from 186 blocks, 26 bags of cement, 2 m³ of sand, 1 m³ of gravel and 30 bars of 10 mm.

Work it out for your own job

Enter the bedrooms and, if you like, the people in the house, then choose a block tank built on site or ready-made polyethylene tanks. Countstruct sizes the tank and lists every material.

Open the septic tank calculator in Countstruct

How to estimate it

  1. Find the capacity

    Size the tank by bedrooms: 2.838 m³ for 1 or 2, 3.785 for 3, 4.542 for 4, 5.678 for 5 or 6, and 0.568 more for each extra bedroom. For a large household, use 0.15 m³ per person if that is more:

    Capacity = max(by bedrooms, People × 0.15 m³)

    Only the 1 to 2 bedroom figure is confirmed as NPC Table B-2. The larger sizes follow the US plumbing code table the NPC is based on; confirm them with your sanitary engineer.

  2. Size a block tank

    The liquid is 1.2 m deep with 0.3 m of air above, so the tank is 1.5 m deep inside. It is about twice as long as it is wide, never smaller than the 1.5 × 0.9 m minimum, with each side rounded up to 5 cm:

    Width = max(0.9, √(Capacity ÷ 2.4))

    Length = max(1.5, Capacity ÷ (1.2 × Width))

    A baffle wall across the width, two thirds of the way from the inlet, makes the two chambers.

  3. Count the blocks

    The walls are 6" hollow blocks (0.15 m thick), at 12.5 blocks per m² plus 5%:

    Walls = (2 × (L + W) + 4 × 0.15) × 1.5 + W × 1.5

    Blocks = ⌈Walls × 12.5⌉ + 5%

  4. Add the slabs, cement, sand, gravel and bars

    Floor and cover slabs are 0.10 m of Class A concrete, 0.30 m larger than the inside each way. The walls are laid in 6" mortar and the inside faces plastered:

    Slabs = 2 × (L + 0.30) × (W + 0.30) × 0.10 m³

    Cement = Slabs × 9 + Walls × 1.018 + Plaster × 0.192 bags

    Sand = Slabs × 0.5 + Walls × 0.0844 + Plaster × 0.016 m³; Gravel = Slabs × 1.0 m³

    Slabs take 10 mm bars every 0.20 m both ways; the walls take 4.28 m of 10 mm bar per m².

Worked example

A 3-bedroom house with a 6" hollow block septic tank. Capacity 3.785 m³.

Item Calculation Quantity to order
Inside width √(3.785 ÷ 2.4) = 1.256 → 1.30 m 1.30 m
Inside length 3.785 ÷ (1.2 × 1.30) = 2.43 → 2.45 m 2.45 m
Walls with baffle (2 × 3.75 + 0.6) × 1.5 + 1.30 × 1.5 14.1 m²
6" hollow blocks 14.1 × 12.5 = 176.25 → 177, + 9 (5%) 186 blocks
Floor and cover slabs 2 × 2.75 × 1.60 × 0.10 0.88 m³
Plaster, inside 2 × 3.75 × 1.5 + 2 × 1.30 × 1.5 15.15 m²
Cement, 40 kg 0.88 × 9 + 14.1 × 1.018 + 15.15 × 0.192 = 25.2 26 bags
Sand 0.88 × 0.5 + 14.1 × 0.0844 + 15.15 × 0.016 = 1.87 2 m³
Gravel 0.88 × 1.0 1 m³
10 mm bars, 6 m 19 for the slabs + ⌈14.1 × 4.28 ÷ 6⌉ = 11 for the walls 30 bars
Tie wire, #16 270 crossings × 0.30 ÷ 53 = 1.53 kg 2 kg

Leave two manholes of at least 0.50 m in the cover slab, one over each chamber. Keep the tank at least 15 m from any well and outside the house. As ready-made polyethylene tanks of 2,000 L, the same house needs ⌈3.785 ÷ 2⌉ = 2 tanks; check the size with the supplier.

What the Countstruct calculator adds

Countstruct septic tank calculator

  • Capacity by bedrooms, or by people for a large household.
  • A 6" hollow block tank built on site, or ready-made 2,000 L polyethylene tanks.
  • Inside size, blocks, Class A slabs, mortar, plaster, cement, sand, gravel, 10 mm bars and tie wire.
  • Prices from a built-in price book you can edit, and the result goes into a project bill of quantities.
Open the septic tank calculator in Countstruct

Questions

What size septic tank does a 2-bedroom house need?

2,838 litres (2.838 m³) of liquid capacity, from NPC Table B-2 for 1 or 2 bedrooms. As a block tank that is 2.15 × 1.10 m inside and 1.5 m deep.

How many hollow blocks for a septic tank?

It depends on the size. A 3-bedroom tank, 2.45 × 1.30 × 1.5 m inside, takes about 186 blocks of 6" including the baffle wall and 5% extra.

Why does a septic tank need two chambers?

The National Plumbing Code requires two chambers so solids settle in the first. The inlet chamber holds at least two thirds of the capacity, so the baffle sits two thirds of the way from the inlet.

How far must a septic tank be from a well?

Keep it at least 15 m from any well, and outside the house.